  general description the fiber optic monitor and control evaluation kit (ev kit)provides a hardware and software interface for evaluat- ing the ds1854, ds1857, ds1858, and ds1859. the kit includes microsoft windows -compatible software that performs the 2-wire functions required to changethe device settings and monitor the device registers. in addition to the general communications functions pro- vided by the software, it allows the resistors?tempera- ture-addressed look-up tables to be programmed from a text file. the kit hardware includes test points that allow inputs to be connected to the external stimuli and outputs to be monitored by test equipment; jumpers can be used to configure the device for the customer? application. ev kit contents list floppy disk with ev kit softwareevaluation board with ds3900 communication module serial cable not included (see required equipment section) features ? supports ds1854, ds1857, ds1858, and ds1859 ? windows software allows easy access to devicefunctionality and handles 2-wire communication ? zif socket allows all four device types to beevaluated from a single board ? software allows user to program variableresistors from a text file ? real-time monitoring software continuouslymonitors temperature, v cc , monitor inputs, and status bytes ? external temperature sensor footprint forevaluating the ds1857 ? ev kits software can be used to configure ormonitor the device in a customers application circuit evaluates: ds1854/ds1857/ds1858/ds1859 fiber optic monitor and control evaluation kit ______________________________________________ maxim integrated products 1 ordering information rev 0; 05/04 for pricing, delivery, and ordering information, please contact maxim/dallas direct! at 1-888-629-4642, or visit maxim? website at www.maxim-ic.com. microsoft and windows are registered trademarks of microsoftcorp. part evaluates ic package ds185xevkit ds1854/57/58/59* 16-pin tssop designation qty description c1, c2 2 1.0? cer am i c cap aci tor s, 0 805 c3 1 0.1? cer am i c cap aci tor , 0805 j1 1 ban ana j ack, 4m m , r ed , p c b oar d m ount, d el tr on 164- 6219 j2 1 ban ana j ack, 4m m , b l ack, p c b oar d m ount , d el tr on 164- 6218 jp1, jp2, jp3 3 h ead er connector s, m al e, 100- m i l , 1 x 6 jp4 1 h ead er connector , m al e, 100- m i l , 2 x 4 jp5, jp6 2 h ead er connector s, m al e, 100- m i l , 2 x 8 jp8 1 h ead er connector , m al e, 100- m i l , 1 x 2 tp1?p19 19 test p oi nts m1 1 d s 3 900 ser i al com m uni cati on m od ul e u1 1 test socket, e n p las , ots - 24- 0.65- 01 u2 1 lm 50, s ot 23 ( op ti onal ) component list * device samples are not included in the ev kit and must be ordered separately (tssop package). downloaded from: http:///
evaluates: ds1854/ds1857/ds1858/ds1859 fiber optic monitor and control evaluation kit 2 _____________________________________________________________________ required equipment device samples (tssop package) serial cable (radio shack 26-117, digi-keyae1020-nd, or equiv.) ibm-compatible pc with a 3.5in floppy drive andwin95/winnt 4.0 or higher power supply (3.3v or 5v) quick start 1) copy the executable file (ds185xevkit.exe) fromthe floppy disk to the pc? hard drive, or the latest version of the ev kit software can be down- loaded from ftp.dalsemi.com/pub/system_exten- sion/evkits/ds185xevkit/. 2) install the ds3900 module on the ev kit board if it wasnot pre-installed when the kit was received (figure 2). make sure the ds3900? switches are in the on posi- tion. 3) connect the serial cable from the ds3900 to the pc. 4) choose a device to evaluate and insert it into thesocket (top justified). be sure to match up the pin 1 indicator on the device to the upper left corner of the socket. note : the dot on the corner of the package indicates pin 1; see figure 2 for the correct orienta-tion of the device in the socket. 5) place jumpers on board for the device that is being evaluated as shown in figure 3. these are defaultjumper settings, which can be changed later as required by the application. 6) connect a 3.3v or 5v power supply to the board(figure 2). 7) open the software, and select the device that youare evaluating on the startup screen. the following sections describe the available evaluationhardware and software features. detailed description to aid in evaluating the devices, all of the input andoutput signals have test points to allow connection of the signals to test equipment. in the case of inputs, these test points can be used to connect the device to external stimuli, which, depending on the input, may be digital input for in1 or in2, or an analog input for one of the monitoring pins. the outputs (out1, out2) can be connected to an oscilloscope or external circuitry as required for prototyping and evaluation. see the schematic diagram in figure 12 and the layout in figure 13 for more detail regarding kit board? circuitry. because the pinouts of the ds1854/ds1857/ds1858/ ds1859 are not identical, tables printed on the left and right side of the board show the function of the test points and jumpers by device type. use the appropriately fiber optic monitor and control evaluation kit figure 1. ds1854/ds1857/ds1858/ds1959 kit contents downloaded from: http:///
evaluates: ds1854/ds1857/ds1858/ds1859 fiber optic monitor and control evaluation kit _____________________________________________________________________ 3 labeled column for the device being evaluated (e.g., ?4for ds1854). since the ds1859 was released after the ev kit, use the jumpers/test points labeled ?8?when evalu- ating the ds1859. check our ftp site for the latest ver- sion of the ev kit software. jumpers are present to allow the pins that can be digital inputs to be connected to v cc or gnd. for any given device, some of the pins will be analog inputs or outputs,so be advised that jumper settings should be monitored carefully to prevent connecting an output to v cc or gnd, and to prevent the analog input from being connected toan invalid level. for example, the first jumper for a ds1854 is out1, which is an open-collector output. connecting it to v cc could cause bus contention if the device? internal driver is driving the output low. thejumper settings as they relate to specific devices are explained further in the evaluation sections below. one similarity between all of the devices is the resistor operation. all the devices have two low-temperature coef- ficient digital resistors. the resistors have test points located on the upper right-hand corner of the board, and jumpers are present that allow the low ends of the resis- ds3900 ground connector v cc connector ds1854/57/58/59 socket (pin 1) ds1854/57/58/59 pin 1 bubble v cc out1 in1 out2 in2wp rhiz gnd ds1854 resistor jumpers (ds1854, ds1857, ds1858, and ds1859) external temperature sensor (ds1857 only) input v cc a0a1 a2 wp rhiz mon1 gnd ds1857 input v cc out1 in1 out2 in2wp mon1 gnd ds1858/ds1859 input vcc h0 l0 gnd gnd*l1 h1 v cc *never jumper v cc to gnd jumper to connect external temperature sensor footprint figure 2. ev kit hardware (rev 2.0) figure 3. default jumper settings downloaded from: http:///
evaluates: ds1854/ds1857/ds1858/ds1859 fiber optic monitor and control evaluation kit 4 _____________________________________________________________________ tors to be connected to ground or the high ends of theresistors to be connected to v cc . note: it is possible to accidentally short v cc to gnd with the resistor jumper block. also, connecting thehigh end of a resistor to v cc and the low end to gnd at the same time may exceed the resistor current specifi-cation (dependent on the resistor setting). take care to avoid these hazards. evaluating the ds1854 the test points and jumpers for the ds1854 are labeledin the ?4?column of the tables printed on the kit board. the ds1854? out1 and out2 outputs are con- nected to jumpers as well as the test points on the kit because these signals are inputs for the ds1857. to prevent bus contention, these jumpers should be removed prior to powering up the kit. a detailed description of all of the jumper settings possible for the ds1854 is provided in table 1. monitor inputs typically, the monitor inputs are driven by a bench sup- ply during evaluation. the software displays the voltages on the monitor pins on the real-time monitoring page. digital outputs out1 and out2 can be sampled at the test points witha multimeter or an oscilloscope for most evaluation pur- poses. the outputs are open drain so a pullup resistor (not provided on the pc board) must be used to output a high state. the test points can also be connected to external circuitry for evaluation. resistor terminals the resistor test points can be used to attach theds1854? resistors to external circuitry for evaluating the device. if the low terminal requires a connection to ground or the high terminal requires a connection to v cc it can be done by the jumper block. if the resistor valuesare not changing as expected with adjustments by the software, check the write-protect (wp) pin to make sure it is grounded. if the device is write protected, it can pre- vent access to the digital resistors. if the resistors appear to be high impedance, check to see if the rhiz pin is dis- connected or connected to v cc . this disconnects the resistors from their terminals. if rhiz is grounded, theresistor should operate normally. evaluating the ds1857 the test points and jumpers for the ds1857 are labeledin the ?7?column of the tables printed on the kit board. the last jumper position for the ds1857 is the mon1 input. this jumper is present because the same pin is a digital input for the ds1854, but it should always be disconnected when evaluating a ds1857. a detailed description of all of the jumper settings possi- ble for the ds1857 is provided in table 2. address inputs the address inputs, a2, a1, and a0 can determine themain 2-wire address for the ds1857. the possible ds1857 addresses that can be configured using the address inputs are shown in table 3. these inputs can be disabled using the configuration register (89 hex), which sets the 2-wire address equal to the value stored in the device address register (8c hex). when the kit soft- ware is first launched, it assumes a main device address of a2h. if another address is set using the jumpers or the eeprom configuration registers, the software address must be set using the 2-wire page. monitor inputs typically, the monitor inputs are driven by a bench sup- ply during evaluation. the software displays the voltages on the monitor pins on the real-time monitoring page. fiber optic monitor and control evaluation kit ds1854 jumper name jumper settings function out1 do not connect output 1. open-collector output for in1. in1 v cc or gnd input 1. digital input corresponding with out1. out2 do not connect output 2. open-collector output for in2. in2 v cc or gnd input 2. digital input corresponding with out2. wp v cc , nc, or gnd write protect. connect to gnd to allow the eeprom to be written. disconnect orconnect to v cc to write protect the memory. rhiz v cc , nc, or gnd resistor high-impedance enable. connect to v cc or leave disconnected to force the resistor terminals to enter a high-impedance state. connect to gnd to enable theresistors. lm50 (right side of board) do not connect used for ds1857 only. table 1. ds1854 jumper settings downloaded from: http:///
evaluates: ds1854/ds1857/ds1858/ds1859 fiber optic monitor and control evaluation kit _____________________________________________________________________ 5 external temperature sensor the ds1857 is designed and manufactured to operate with an lm50 temperature sensor. to allow the evalua- tion of the ds1857 with an lm50, a footprint for the lm50 is added to the right side of the board. this allows a sot-23 lm50 to be added to the board by the customer. additionally, a jumper is next to the lm50 that allows the external temperature sensor to be dis- connected from the test point and the ds1857. this makes it possible to evaluate temperature input of the ds1857 using the test point and a voltage supply. to evaluate the ds1857 with the lm50, place the jumper on the board to connect the ds1857 to the lm50? out- put. resistor terminals the resistor test points can be used to attach theds1857? resistors to external circuitry for evaluating the device. if the low terminal requires a connection to ground or the high terminal requires a connection to v cc , it can be done by the jumper block. if the resistor values are not changing as expected with adjustmentsby the software, check the wp pin to make sure it is grounded. if the device is write protected, it can pre- vent access to the digital resistors. if the resistors appear to be high impedance, check to see if the rhiz pin is disconnected or connected to v cc . this discon- nects the resistors from their terminals. if rhiz isgrounded, the resistor should operate normally. evaluating the ds1858 or the ds1859 the test points and jumpers for the ds1858 and theds1859 are labeled in the ?8?column of the printed tables on the kit board. the ds1858/59? out1 and out2 outputs are connected to the corresponding jumpers as well as the test points on the kit because these signals are inputs for the ds1857. to prevent bus conflicts, these jumpers should be removed prior to pow- ering up the kit. a detailed description of all of the jumper settings for the ds1858/59 is provided in table 4. monitor inputs typically, the monitor inputs are driven by a bench sup-ply during evaluation. the software displays the voltages on the monitor pins on the real-time monitoring page. ds1857 jumper name jumper settings function a0 v cc or gnd address input a0. see the address inputs section. a1 v cc or gnd address input a1. see the address inputs section. a2 v cc or gnd address input a2. see the address inputs section. wp v cc , nc, or gnd write protect. connect to gnd to allow the eeprom to be written. disconnector connect to v cc to write protect the memory. rhiz v cc , nc, or gnd resistor high-impedance enable. connect to v cc or leave disconnected to force the resistor terminals to enter a high-impedance state. connect to gndto enable the resistors. mon1 do not connect monitor input 1. connect to an external analog source through the test pointfor evaluating the a/d converter. lm50 (right side of board) connected or disconnected external temperature sensor. add this jumper to connect the lm50 (ifpopulated by customer) to the ds1857? external temperature sensor pin. remove this jumper to disconnect the temperature sensor, which allows the pin to be driven by an external voltage connected to the test point. table 2. ds1857 jumper settings a2 a1 a0 corresponding main device address (hex) 000 a 0 001 a2* 010 a 4 011 a 6 100 a 8 101 a a 110 a c 111 a e table 3. ds1857 address settings * default jumper and software addresses. downloaded from: http:///
evaluates: ds1854/ds1857/ds1858/ds1859 fiber optic monitor and control evaluation kit 6 _____________________________________________________________________ digital outputs out1 and out2 can be sampled at the test points witha multimeter or an oscilloscope for most evaluation pur- poses. the outputs are open drain so a pullup resistor (not provided on the pc board) must be used to output a high state.the test points can also be connected to external circuitry for evaluation. resistor terminals the resistor test points can be used to attach theds1858/59? resistors to external circuitry for evaluating the device. if the low terminal requires a connection to ground or the high terminal requires a connection to v cc , it can be done by the jumper block. if the resistor values are not changing as expected with adjustmentsby the software, check the wp pin to make sure it is grounded. if the device is write protected, it can pre- vent access to the digital resistors. if the resistors appear to be high impedance, check to see if the rhiz pin is disconnected or connected to v cc . this discon- nects the resistors from their terminals. if rhiz isgrounded, the resistor should operate normally. software the latest version of the ev kit software can be down-loaded from ftp.dalsemi.com/pub/system_extension/ evkits/ds185xevkit. to start the application, double-click on the executable file ds185xevkit.exe. when the following dialog box appears, choose the device that is being evaluated and click ok (figure 4). if the board is not connected properly, a message boxwill appear and the software will open (figure 5). although it is possible to browse the functions available in the software when the evaluation board has not been found, the software does not attempt to communicate with the ic on the board. make sure the ds3900 is con- nected properly to the board and the pc (see the troubleshooting section), then close the software and retry. if the board is operating properly, the softwarewill open with no message (figure 6). fiber optic monitor and control evaluation kit ds1858/ds1859 jumper name jumper settings function out1 do not connect output 1. open-collector output for in1. in1 v cc or gnd input 1. digital input corresponding with out1. out2 do not connect output 2. open-collector output for in2. in2 v cc or gnd input 2. digital input corresponding with out2. wp v cc , nc, or gnd write protect. connect to gnd to allow the eeprom to be written. disconnect orconnect to v cc to write protect the memory. mon1 do not connect monitor input 1. connect to an external analog source through the test point forevaluating the adc. lm50 (right side of board) do not connect used for ds1857 only. table 4. ds1858/ds1859 jumper settings figure 4. device selection dialog box figure 5. no ev kit found message box downloaded from: http:///
evaluates: ds1854/ds1857/ds1858/ds1859 fiber optic monitor and control evaluation kit _____________________________________________________________________ 7 general page the kit software is identical for all devices with theexception of the ds1858/59, which has an extra monitor input on applicable pages. the ds1857 temperature sensor is denoted as external because it is designed to work with an external temperature sensor (lm50). all the values shown on the general page are read-only. click on read or type alt + r to update the display? data. the general page also displays the main and auxiliary deviceaddresses. if the device is not found, verify that the soft- ware address matches the address register and/or the jumper settings if evaluating a ds1857. manual resistor control page the manual resistor control page disables the tempera-ture update function each time the page is entered and allows read and write access to the resistor registers. to change the resistor values, use either the spin con- trol or type a position (0 to 255 decimal) and click the write button. to read the present value of the resistor register, click the read button. this page also allows the temperature look-up table mode bits and the resis- tor high-impedance control and status (hizsta is read-only) bits to be adjusted or monitored using the read and write bits buttons. when the user leaves this page, the mode bits control- ling the temperature update function are typically restored, and the automated temperature look-up func- tion is re-enabled. to remain in manual resistor mode after this page is exited, select the remain in manual resistor mode check box. this allows the user to exit the manual resistor control page without re-enablingthe temperature look-up function. to exit the manual resistor mode, the remain in manual resistor mode check box must be disabled and the user must leavethe manual resistor control page. memory page the memory page can be used to read and write datato or from any of the device? registers. to write to a register(s), first select the register? table, then use one of the four available write functions (see read and write functions ). to read data, select a table, and then use one of the three available read functions. figure 6. general page downloaded from: http:///
evaluates: ds1854/ds1857/ds1858/ds1859 fiber optic monitor and control evaluation kit 8 _____________________________________________________________________ read and write functions single byte read and write functions to read a single byte, type a hexadecimal address andclick the corresponding read button. to write a single byte, type the byte? address and the new data (bothhexadecimal) and click the corresponding write button. the read or write is performed in the selected table. twosingle byte read/write buttons have been provided for the user? convenience; they both perform the same function. 2-byte read and write functions the 2-byte functions are present to simplify dealing withthe 2-byte functional registers present on these devices such as the v cc , temperature, and the monitor registers. to use the 2-byte read function, type in the address of thelsb, and click the read button to read two consecutive bytes beginning at that address. to use the write func- tion, type the address of the lsb, enter both new data values, and click the write button. the read or write will be performed in the selected table. two 2-byte read/writebuttons have been provided for the user? convenience; they both perform the exact same function. page read and page write functions the page read and write functions are present to sim-plify changing large amounts of data at a time, such as changing the entire contents of a resistor look-up table. the page numbers are equal to the 5 msbs of the reg- ister addresses being adjusted, and the eight editboxes correspond to the 3 lsbs of the register addresses. the page-read function allows an entire memory page (8-bytes) to be read by selecting the page number on either spin control and clicking the read button. to write a page, select the page number, changing all eight data values to their new contents,and clicking the write button. either spin control can be used to select the page, and the operation will be per-formed in the selected table. memory fill tool the memory fill tool allows a range of registers to be written to the same value. to use the fill tool, type the data value to fill, the start and stop addresses of the memory range to be adjusted, and click the fill now button. the memory fill will affect the selected table only. 2-wire page the 2-wire page provides the user with access to the 2-wire communications functions of the ds3900, and allows the software address used by all sections of the ev kit software to be adjusted. although the 2-wire page? main purpose is for debugging, it can allow the kit to be used to communicate with any 2-wire device. clicking on a 2-wire control will immediately perform the corresponding function listed in table 5. fiber optic monitor and control evaluation kit figure 7. manual resistor control page downloaded from: http:///
evaluates: ds1854/ds1857/ds1858/ds1859 fiber optic monitor and control evaluation kit _____________________________________________________________________ 9 main device address if an address other than a2h is desired to test either theds1857? address pins, or to use the eeprom address function, the main device address must be changed in this window to match the address of the device. the find button the find button searches all the possible addresses on the 2-wire bus for devices that respond to those address- es, and it reports back the addresses that were acknowl- edged in the box below the button. depending on the ds1854/ds1857/ds1858/ds1859? current mode it responds to one or two addresses. the main device address can be any value from 00h to feh. the auxillary address, if used, is always a0h. this button is very useful to determine the address the device is responding to when the software reports a communication error. using the 2-wire page to access a device to access a device using the 2-wire page, all of the itemsthat are accomplished by a 2-wire master have to be manually done by the software user. for example, to write a byte (34h to 80h) to a ds1857 with a device address of a2h, the following sequence must be completed. 1) main device address must be set to a2h. 2) send start (issues 2-wire start condition). 3) send write (writes a2h, the device address, over 2- wire bus). 4) send data 80h (writes 80h, the data address, over the 2-wire bus). 5) send data 34h (writes 34h, the data, over the 2-wire bus). 6) send stop (issues a 2-wire stop condition). although this is not a quick or refined approach, it pro- vides maximum flexibility for debugging 2-wire prob- lems or to communicate with ics that do not have custom software. file page saving register settings to a text file the file page allows the user to copy all the registersettings from select memory tables and send the data to a text file. the check boxes choose which tables are copied when the dump button is pressed. a dialog box prompts the user for a file name and location to savethe file. the text file is saved using a tab-delimited for- mat, which is easy to import into excel. any errors that were encountered during programming are reported in the status box. figure 8. memory page downloaded from: http:///
evaluates: ds1854/ds1857/ds1858/ds1859 fiber optic monitor and control evaluation kit 10 ____________________________________________________________________ fiber optic monitor and control evaluation kit figure 9. 2-wire page figure 10. file page downloaded from: http:///
evaluates: ds1854/ds1857/ds1858/ds1859 fiber optic monitor and control evaluation kit ____________________________________________________________________ 11 functions description send start performs 2-wire start and repeated start functions. send write writes the main device address listed in the software 2-wire settings section over the 2-wire bus. send read writes the main device address +1 (if a2h is listed it writes a3h) over the 2-wire bus. the main device address islisted in the software 2-wire settings section. send byte sends the byte to the right of the button over the 2-wire bus. read w/ack reads one byte and acknowledges (ack) the data transfer during the 9th clock cycle. read w/nack reads one byte and does not acknowledge (nack) the data transfer during the 9th clock cycle. send stop performs 2-wire stop function. 9 clocks clocks the 2-wire bus nine times. this can be used followed by the stop command to reset the 2-wire bus. find the find button searches for all 2-wire devices present on the 2-wire bus and lists their addresses. this is usefulif the address register has been modified from the default value, because a device cannot be addressed to read the address register if its device address is not known. table 5. 2-wire page functions description figure 11. real-time monitoring page downloaded from: http:///
evaluates: ds1854/ds1857/ds1858/ds1859 fiber optic monitor and control evaluation kit 12 ____________________________________________________________________ programming a device from a text file the device? resistor look-up tables can be programmedfrom a text file. to program the tables, press the gen template button to create a template file in the proper for- mat. it prompts the user for a file name and location tosave the template file. open the template file in excel. a table is present for each resistor? look-up table. modify the data for each table until the spreadsheet reads as desired. if it is desired to only program one look-up table, delete the second table, but be careful not to change any of the formatting of the other table. once the contents of the table are correct, save the file as a text file. press the fill button in the kit software. a dialog prompts for the location and name of the text file. navigate to the file,select it, and press ok . the program parses the file look- ing for inconsistencies. if everything appears okay, it exe- cutes the fill instruction. the program reports what it has done in the status window, which should be checked to verify that no errors occurred. real-time page the real-time page displays the current temperature,v cc , and external monitoring signals at regular time intervals (0.1s). it also displays the monitor alarm flagsand resistor values. the clear button can be used to clear all of the miscella- neous flags, which allows the user to easily spot the order that flag raising events occur. when the clear button is pressed, the software clears the flags and begins pulling the flag registers much quicker than the normal 0.1s inter- val of the page. the register values read are saved to a buffer, and the display is updated at a fast but readable rate so the software user can see the order the flags changed. although this does not provide the information exactly real-time, it does read the data from the part and present it at a rate the user can process. in-circuit evaluation the ev kit can be used to communicate with devices thathave already been placed in an application circuit. to use the ev kit to communicate with an in-circuit device, v cc must be applied to the kit, and sda, scl, and the kit? ground must be connected to the applica- tion board. whenever possible, the kit? v cc supply should remain equal to that of the application board toprevent communication problems. the ds3900 has built in 4.7k ? pullups that can be used for 2-wire communica- tion. if the application circuit also has pullups, theds3900? pullups can be disabled by placing both of the dip switches in the off position. this prevents the ds3900 and the device from having to sink large cur- rents to pull the sda and scl busses low. once these connections are made, all of the evaluation software functions can be used to evaluate the device in-circuit. te c h nical support for additional technical support, please email yourquestions to mixedsignal.apps@dalsemi.com. fiber optic monitor and control evaluation kit symptom cause solution evaluation board not found. board not connected properly. make sure to connect the cable from the db9 connector onthe ds3900 to the pc. verify the ds3900 is firmly in place. verify the power is on. no output on out1/out2. no input on in1/in2. verify jumper settings. resistance not reading correctly. type of multimeter used. force a current and measure the voltage to get resistance. communication error device is not communicatingwith pc. verify main device address in the software matches theaddress set on the board (ds1857). verify the device is in the socket and the device type is the one you intended to evaluate. verify the ds3900 is firmly in place. make sure switches are on. not able to write to eeprom. device is write protected. verify that wp is connected to gnd. tr oubleshooting downloaded from: http:///
evaluates: ds1854/ds1857/ds1858/ds1859 fiber optic monitor and control evaluation kit ____________________________________________________________________ 13 db9 ds3900 ds1854/7/8/9 test socket (top justify part) p1p2 p3 n.c. gnd p11?dap10?cl gnd v cc p9p8 1 f p7p6 p4p5 ds1854/ds1857/ds1858/ds1859 i/o 12 3 4 5 6 7 8 out1 in1 out2 in2wp rhiz mon1mon2 a0a1 a2 wp rhiz mon1mon2 extmp out1 in1 out2 in2wp mon1mon2 mon3 gnd jumper block connected as labeled. use jumpers to connect signals to v cc or ground for evaluation. note: do not connect v cc and gnd v cc lm50 not populated. use a jumper to connect it to a ds1857. lm50 pins not used v cc banana jack v cc test point gnd test point gnd banana jack v cc 531 12 3 4 5 6 7 8 9 1011 12 24 v cc v cc h0 l0 gnd gndl1 h1 v cc 0.1 f 2322 21 20 19 6 h1 l1 l0 h0 78 1817 16 15 14 13 sda 4 v cc 12 3 4 5 6 gnd input 2 scl ds1858/ ds1859 ds1857 ds1854 input figure 12. ds1854/ds1857/ds1858/ds1859 evaluation board schematic downloaded from: http:///
evaluates: ds1854/ds1857/ds1858/ds1859 fiber optic monitor and control evaluation kit maxim cannot assume responsibility for use of any circuitry other than circuitry entirely embodied in a maxim product. no circuit patent licenses are implied. maxim reserves the right to change the circuitry and specifications without notice at any time. 14 ____________________maxim integrated products, 120 san gabriel drive, sunnyvale, ca 94086 408-737-7600 2004 maxim integrated products printed usa is a registered trademark of maxim integrated products. dallas is a registered trademark of dallas semiconductor corporation. top layout bottom layout figure 13. evaluation board layout (rev 2.0). newer revisions may vary slightly. downloaded from: http:///


▲Up To Search▲   

 
Price & Availability of DS1854EVKIT

All Rights Reserved © IC-ON-LINE 2003 - 2022  

[Add Bookmark] [Contact Us] [Link exchange] [Privacy policy]
Mirror Sites :  [www.datasheet.hk]   [www.maxim4u.com]  [www.ic-on-line.cn] [www.ic-on-line.com] [www.ic-on-line.net] [www.alldatasheet.com.cn] [www.gdcy.com]  [www.gdcy.net]


 . . . . .
  We use cookies to deliver the best possible web experience and assist with our advertising efforts. By continuing to use this site, you consent to the use of cookies. For more information on cookies, please take a look at our Privacy Policy. X